Low Temperature Type Air Cooled Chiller

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2019-10-12 12:21

  • Browse the number:

    482

Send an inquiries
Company Profile
Suzhou Anshijia Machinery Co., Ltd
Contactaixin:

anshijia(Mr.)  

Email:

telephone:

phone:

Arrea:

Jiangsu

Address:

No.299, Youbi Road, Zhoushi Town, Kunshan City, Suzhou City, Jiangsu Province

Website:

http://www.asj-aircooler.com/ http://anshijia.nntaiqiuzhuo.com/

Product details

A. Product overview

Low temperature air cooled chiller, referred to as low temperature chiller.Because of its liquid temperature in 0-80 degrees and cooling mode for fan cooling, so also known as air-cooled low temperature chiller.


B. Parameters of the product

Low temperature type air cooled chiller

SJ-20AD

Freezing capability

KW/hr(50Hz)

22(-25 Outlet condition)

Power source

V

3∮ 380V~50HZ

Electric current

A

42

Refrigerant

Kind

R404A

FILLING QUANTIT(kg)

9

Power of compressor

KW

13

Quantity of compressor


2

Cooling air volume

m3/h

20000

Power of water pump

KW

1.5

Refrigerated water flow

m3/hr

4

Diameter of freezing water pipe

MM

50

Overall dimension

L(mm)

1955

W(mm)

940

H(mm)

1960

Weight of machine

kg

720


C. Product details

Low-temperature chillers usually use semi-closed piston compressors, which have the following advantages:

1, Suitable for a wide range of pressure, piston compressor can be designed as low pressure, medium pressure, high pressure and ultra-high pressure, and at the same speed, when the exhaust pressure fluctuations, piston compressor exhaust volume remains unchanged.

2, The compression efficiency is high, the piston compressor compressed gas process is a closed system, its compression efficiency is high.

3, Strong adaptability, piston compressor exhaust a wide range, and the impact of gas density on the performance of the compressor than the speed compressor, more suitable for low-temperature condition unit.


Requirements for use of low - temperature air - cooled chillers

1. Depending on the temperature, cooling media have different requirements, 0-40 recommended use of ethylene glycol solution;Low temperature heat conducting oil is recommended for use below 60 c. Flammable liquids such as alcohol are not recommended.

2. The low-temperature chiller should be installed as close as possible to the equipment in use, because the farther the distance is, the greater the lift of the pump and the larger the motor power will be, thus increasing the load of the unit. The pipeline must be insulated to minimize the loss of cooling capacity.

D. FAQ

Q: Can this cold water chiller be powered by 3-phase 220V60Hz?

A: Yes, the compressor motor can support a wide range of power supply systems and may be controlled by a frequency converter to adjust the input/output power supply.

http://www.asj-aircooler.com/